Description
6-Channel RTD Measurement M-module – M390
The M390 is a RTD Measurement M-module featuring six 2-, 3-, or 4-wire high accuracy RTD measurements channels. The M390 is available in four versions:
– PT100 measurement
– PT200 measurement
– PT500 measurement
– PT1000 measurement
Data acquisition is performed by an embedded DSP, transparent for the user, and the conversion result is stored in dual-ported memory. Conversion data can be stored in four different, and per channel selectable, data formats (Celsius, Fahrenheit, Kelvin and Ohms).
Each channel features upper- and lower-alarm levels. If the input goes beyond this range, an interrupt to the host can be issued. The acquisition time is 133 milliseconds for one channel. For each additional enabled channel, 66 milliseconds must be added.
The M390 features autocalibration and optical isolation.